Sample preparation methods used for genetically modified organisms (GMOs) analysis are often time consuming, require extensive manual manipulation, and result in limited amounts of purified protein, which may complicate the detection of low‐abundance GM protein. A robust sample pretreatment method prior to mass spectrometry (MS) detection of the transgenic protein (5‐enolpyruvylshikimate‐3‐phosphate synthase [CP4 EPSPS]) present in Roundup Ready soya is investigated. Liquid chromatography‐multiple reaction monitoring tandem MS (nano LC‐MS/MS‐MRM) was used for the detection and quantification of CP4 EPSPS. Gold nanoparticles (AuNPs) and concanavalin A (Con A)‐immobilized Sepharose 4B were used as selective probes for the separation of the major storage proteins in soybeans. AuNPs that enable the capture of cysteine‐containing proteins were used to reduce the complexity of the crude extract of GM soya. Con A‐sepharose was used for the affinity capture of β‐conglycinin and other glycoproteins of soya prior to enzymatic digestion. The methods enabled the detection of unique peptides of CP4 EPSPS at a level as low as 0.5% of GM soya in MRM mode. Stable‐isotope dimethyl labeling was further applied to the quantification of GM soya. Both probes exhibited high selectivity and efficiency for the affinity capture of storage proteins, leading to the quantitative detection at 0.5% GM soya, which is a level below the current European Union's threshold for food labeling. The square correlation coefficients were greater than 0.99. The approach for sample preparation is very simple without the need for time‐consuming protein prefractionation or separation procedures and thus presents a significant improvement over existing methods for the analysis of the GM soya protein. 相似文献
We have developed a simple protocol for the preparation of 1,2-fluorohydrin by asymmetric hydrogenation of fluorinated allylic alcohols using an efficient azabicyclo thiazole-phosphine iridium complex. The iridium-catalyzed asymmetric synthesis of chiral 1,2-fluorohydrin molecules was carried out at ambient temperature with operational simplicity, and scalability. This method was compatible with various aromatic, aliphatic, and heterocyclic fluorinated compounds as well as a variety of polyfluorinated compounds, providing the corresponding products in excellent yields and enantioselectivities.We have developed a simple protocol for the preparation of 1,2-fluorohydrin by asymmetric hydrogenation of fluorinated allylic alcohols using an efficient azabicyclo thiazole-phosphine iridium complex.相似文献
Let be a cycle of order 4. Write for the maximum number of edges in a balanced 3‐partite graph whose vertex set consists of three parts, each has vertices that have no subgraph isomorphic to . In this paper, we show that , where and is a prime number. Note that from Tait and Timmons's works. Since for every integer , one can find a prime such that , we obtain that . 相似文献
The accurate quantification of neurotransmitter molecules is an indispensable means to reveal the physiological mechanisms of neuro movement in molecular level. However, existing detection strategies cannot fully meet practical needs, and the on‐site and in vivo detection of neurotransmitters in brain remains a great challenge. Here, we report the development of a near infrared light responsive photoelectrochemical (PEC) detection method for in vivo quantification of neurotransmitter dopamine in mouse brain. Under guidance of density function theory calculations, a combination strategy of non‐metal cation doping and defect engineering is introduced to rationally design the micro‐photoelectrodes with excellent biocompatibility and stability and implements the in vivo PEC detection of dopamine in mouse brain. It opens up a new way for the accurate in vivo detection of biomolecules and allows researchers to make novel inquiries for long‐standing questions in a new way. 相似文献
A ratiometric fluorescent hybrid nanoprobe CDs-1 for arginine(Arg),exhibiting high sensitivity(the limit of detection,LOD,being 6.5×10^-8 mol/L) and excellent selectivity and anti-interference ability,was fabricated through fluorescence resonance energy transfer(FRET) and the electrostatic attraction between positively-charged hemicyanine molecules and negatively-charged carbon dots(CDs).Arg can be quantitatively detected in the concentration range from 6.0×10^-5 mol/L to 2.7×10^-4 mol/L.Further,due to its ability to target mitochondrion and low cytotoxicity,intracellular Arg was succes s fully tracked through ratiometric fluorescence imaging. 相似文献
We study the effects of Hawking radiation and bath temperature on quantum steering and entanglement for a two-mode Gaussian state exposed in the background of a black hole and immersed in the two independent thermal baths. We find that both the effects can destroy the quantum steering and entanglement. Quantum steering always exists sudden death for any Hawking temperature and any bath temperature, but entanglement does not in zero-temperature thermal bath. Both the Hawking radiation and the asymmetry of thermal baths can induce the asymmetry of quantum steering, but the latter effect is much weaker than the former. An unintuitive result is that the observer who stays in the Hawking radiation or in the thermal bath with higher temperature has more stronger steerability than the other one. We also find that Hawking radiation and thermal noise can change the asymptotic behavior of steering and entanglement versus the squeezing parameter.
In dark matter direct detection experiments,neutron is a serious source of background,which can mimic the dark matter-nucleus scattering signals.In this paper,we present an improved evaluation of the neutron background in the PandaX-II dark matter experiment by a novel approach.Instead of fully relying on the Monte Carlo simulation,the overall neutron background is determined from the neutron-induced high energy signals in the data.In addition,the probability of producing a dark-matter-like background per neutron is evaluated with a complete Monte Carlo generator,where the correlated emission of neutron(s)andγ(s)in the(α,n)reactions and spontaneous fissions is taken into consideration.With this method,the neutron backgrounds in the Run 9(26-ton-day)and Run 10(28-ton-day)data sets of PandaX-II are estimated to be(0.66±0.24)and(0.47±0.25)events,respectively. 相似文献